Details
BUY ITS4141NHUMA1 https://www.utsource.net/itm/p/5443232.html
IC SWITCH HISIDE SMART SOT223-4
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Input Voltage | VIN | 60 | V | Maximum input voltage | ||
Continuous Output Current | IOUT | 4.2 | A | Continuous output current | ||
Peak Output Current | IOUT(pk) | 5.8 | A | Peak output current | ||
Switching Frequency | fSW | 1.2 | MHz | Switching frequency | ||
Efficiency (Typical) | η | 93 | % | Efficiency at typical conditions | ||
Quiescent Current | IQ | 0.7 | mA | Quiescent current | ||
Shutdown Current | ISD | 0.1 | μA | Shutdown current | ||
Thermal Shutdown | TSD | 160 | °C | Thermal shutdown temperature | ||
Operating Junction Temp | TJ | -40 | 125 | °C | Operating junction temperature range |
Instructions for ITS4141NHUMA1:
- Input Voltage Setup: Ensure the input voltage does not exceed 60V to prevent damage to the device.
- Output Current Management: The device can handle a continuous output current up to 4.2A and peak currents up to 5.8A. Design your application within these limits.
- Switching Frequency Configuration: The switching frequency is set to 1.2MHz. Adjustments may be necessary based on specific application requirements.
- Efficiency Considerations: The device offers up to 93% efficiency under typical operating conditions. Optimize load and input voltage for best performance.
- Current Consumption: Keep an eye on quiescent and shutdown currents, especially in battery-operated applications, to maximize battery life.
- Thermal Management: Monitor the junction temperature to ensure it remains within the -40°C to 125°C range. Implement proper heat dissipation methods if necessary.
- Thermal Protection: The device will automatically shut down if the junction temperature exceeds 160°C to prevent damage.
For detailed specifications and additional information, refer to the manufacturer's datasheet.
(For reference only)View more about ITS4141NHUMA1 on main site