Details
BUY TLP281BL https://www.utsource.net/itm/p/6375714.html
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Forward Voltage | VF | IF = 10 mA | 1.0 | 1.2 | 1.4 | V |
Peak Forward Current | IFM | Tj = 25°C | - | - | 30 | mA |
Continuous Forward Current | IF | Tj = 75°C, Pulse Width ≤ 1 s | - | - | 10 | mA |
Reverse Voltage | VR | - | - | 5 | V | |
Output Collector-Emitter Saturation Voltage | VCE(sat) | IC = 5 mA, IF = 5 mA | 0.2 | 0.3 | 0.4 | V |
Output Collector Leakage Current | ICEO | VCE = 5 V, Tj = 25°C | - | 10 | 100 | nA |
Isolation Voltage | BVS | Test Condition: 1 minute | - | - | 2500 | Vrms |
Operating Temperature | Topr | -40 | - | 85 | °C | |
Storage Temperature | Tstg | -40 | - | 100 | °C |
Instructions for Use:
Mounting and Handling:
- Handle the TLP281BL with care to avoid damage.
- Ensure proper mounting on a PCB to maintain electrical isolation and thermal performance.
Electrical Connections:
- Connect the forward current (IF) within the specified limits to prevent overheating or damage.
- Ensure reverse voltage (VR) does not exceed the maximum rating to avoid breakdown.
Thermal Management:
- Operate within the recommended temperature range to ensure reliable performance.
- Consider heat dissipation if operating near the upper temperature limit.
Testing:
- When testing the device, do not exceed the peak forward current (IFM) or isolation voltage (BVS) ratings.
- For accurate leakage current measurements, ensure test conditions match those specified in the datasheet.
Storage:
- Store the device in a dry, cool place within the storage temperature range to prevent degradation.
Safety:
- Always follow safety guidelines when handling electronic components.
- Ensure proper grounding and use appropriate protective equipment.