Details
BUY BH1715FVC-TR https://www.utsource.net/itm/p/6426137.html
AMBIENT LIGHT SENSOR 6-WSOF
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | VDD | Operating | 2.4 | - | 5.5 | V |
Operating Current | IDD | Illuminance: 0.1 lx | - | 0.3 | - | mA |
IDD | Illuminance: 100,000 lx | - | 0.3 | - | mA | |
Measurement Range | LUX | 0.1 | - | 100,000 | lx | |
Output Signal | VOUT | - | - | - | V | |
Conversion Time | Tconv | - | 180 | - | ms |
Instructions for BH1715FVC-TR
Power Supply Requirements:
- Ensure the supply voltage (VDD) is within the range of 2.4V to 5.5V.
Operating Current:
- The device operates with a typical current consumption of 0.3mA regardless of illuminance levels from 0.1 lx to 100,000 lx.
Measurement Range:
- The sensor can measure illuminance from 0.1 lux up to 100,000 lux.
Output Signal:
- The output signal (VOUT) is an analog voltage that corresponds to the detected illuminance level. Refer to the datasheet for specific calibration details.
Conversion Time:
- The conversion time for each measurement is approximately 180 milliseconds.
Installation and Handling:
- Handle the component with care to avoid damage.
- Ensure proper grounding and shielding to minimize noise interference.
Application Considerations:
- For optimal performance, place the sensor in a location where it can directly detect the ambient light without obstruction.
- Calibration may be necessary depending on the application requirements.