Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Input Voltage | V_IN | 2.7 | - | 5.5 | V | Operating input voltage range |
Output Voltage | V_OUT | - | 3.3 | - | V | Regulated output voltage |
Quiescent Current | I_Q | - | 1.0 | - | μA | Quiescent current at no load |
Dropout Voltage | V_DROPOUT | - | 200 | - | mV | Typical dropout voltage at 300mA |
Load Current | I_LOAD | - | 300 | - | mA | Maximum continuous output current |
Shutdown Current | I_SD | - | 0.1 | - | μA | Current consumption in shutdown mode |
Operating Temperature | T_OP | -40 | - | 85 | °C | Operating temperature range |
Storage Temperature | T_STG | -55 | - | 150 | °C | Storage temperature range |
Instructions for NRVBS3200T3G
Installation:
- Ensure the input voltage is within the specified operating range (2.7V to 5.5V).
- Connect the input capacitor (typically 1μF) close to the input pin to ensure stability.
- Place an output capacitor (typically 1μF) near the output pin.
Operation:
- The device will regulate the input voltage to a stable 3.3V output.
- Monitor the load current not to exceed 300mA continuously.
- For applications requiring minimal power consumption, use the shutdown feature to reduce current draw to approximately 0.1μA.
Thermal Considerations:
- Ensure adequate heat dissipation if operating near maximum load and high ambient temperatures.
- The device can operate from -40°C to 85°C, but performance may degrade outside of this range.
Storage:
- Store in a dry environment with temperatures ranging from -55°C to 150°C to prevent damage.
Handling:
- Follow standard ESD (Electrostatic Discharge) precautions when handling the component to avoid damage.