Details
BUY IS43DR16640A-3DBI https://www.utsource.net/itm/p/6453836.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | Operating | 1.7 | 1.95 | V | |
| Standby Current | ISB | VCC = 1.8V | 2 | 渭A | ||
| Active Current | IAV | VCC = 1.8V, Active | 30 | mA | ||
| Access Time | tAA | 45 | ns | |||
| Column Address Strobe | tCAC | 25 | ns | |||
| Row Address Strobe | tRAS | 42 | ns | |||
| Write Recovery Time | tWR | 20 | ns | |||
| Precharge Time | tRP | 20 | ns | |||
| Refresh Cycle Time | tREF | 64 | ms | |||
| Data Output Hold Time | tHZ | 10 | ns |
Instructions for Use:
- Power Supply: Ensure the supply voltage (VCC) is within the specified range of 1.7V to 1.95V.
- Current Considerations: Monitor standby and active currents to ensure they do not exceed typical values (2渭A in standby, 30mA in active).
- Timing Parameters:
- Ensure all timing parameters such as access time (tAA), column address strobe (tCAC), row address strobe (tRAS), write recovery time (tWR), precharge time (tRP), refresh cycle time (tREF), and data output hold time (tHZ) are adhered to for reliable operation.
- Initialization:
- Before performing any read or write operations, initialize the device according to the manufacturer's guidelines.
- Refresh Operations:
- Perform refresh cycles at intervals not exceeding the maximum refresh cycle time (tREF) to maintain data integrity.
- Data Integrity:
- Ensure proper handling of data input/output signals, respecting the data output hold time (tHZ) to prevent data corruption.
- Operating Environment:
- Operate the device within recommended environmental conditions to avoid damage or malfunction.
For detailed application-specific instructions and further information, refer to the datasheet provided by the manufacturer.
(For reference only)View more about IS43DR16640A-3DBI on main site