Details
BUY HFA140NJ60C https://www.utsource.net/itm/p/6526730.html
HEXFRED Ultrafast, Soft Recovery Diode
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Breakdown Voltage | V(BR)DSS | - | 600 | - | V | Drain-to-Source Breakdown Voltage |
| Continuous Drain Current | ID | - | 14 | - | A | Continuous Drain Current at TC = 25掳C |
| Power Dissipation | PD | - | 180 | - | W | Total Power Dissipation at TC = 25掳C |
| Junction Temperature | TJ | - | - | 175 | 掳C | Maximum Junction Temperature |
| Gate Charge | QG | - | 93 | - | nC | Total Gate Charge |
| Input Capacitance | Ciss | - | 1660 | - | pF | Input Capacitance at VDS = 400V, VGS = 0V |
| Output Capacitance | Coss | - | 400 | - | pF | Output Capacitance at VDS = 400V, VGS = 0V |
| Reverse Transfer Capacitance | Crss | - | 430 | - | pF | Reverse Transfer Capacitance at VDS = 400V, VGS = 0V |
Instructions for Use:
Installation:
- Ensure the HFA140NJ60C is installed in a circuit where the maximum drain-to-source voltage does not exceed 600V.
- Verify that the continuous drain current does not exceed 14A to prevent overheating and damage.
Thermal Management:
- The device can dissipate up to 180W of power at an ambient temperature of 25掳C. Adequate heat sinking may be required to maintain this performance at higher temperatures.
- Monitor the junction temperature to ensure it does not exceed 175掳C.
Gate Drive:
- Be mindful of the gate charge (QG) when designing the gate drive circuitry. The typical value is 93nC, which affects switching speeds and drive requirements.
Capacitance Considerations:
- Account for the input capacitance (Ciss), output capacitance (Coss), and reverse transfer capacitance (Crss) in your design. These parameters influence the switching behavior and can affect overall circuit performance.
Storage and Handling:
- Store the device in a dry environment and handle with care to avoid damage to the sensitive components.
- Follow proper anti-static precautions during handling to prevent damage from electrostatic discharge.
For detailed specifications and application notes, refer to the datasheet provided by the manufacturer.
(For reference only)View more about HFA140NJ60C on main site