Details
BUY PM75CHA060 https://www.utsource.net/itm/p/6527942.html
NULL
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Input Voltage | V_IN | Operating Range | 4.5 | - | 60 | V |
| Output Voltage | V_OUT | Adjustable Range | 1.2 | - | 38 | V |
| Switching Frequency | f_SW | - | 650 | - | kHz | |
| Quiescent Current | I_Q | No Load | - | 70 | - | 渭A |
| Efficiency | 畏 | At 5V in, 3.3V out | - | 90 | - | % |
| Output Current | I_OUT | Continuous | - | - | 3 | A |
| Shutdown Current | I_SD | V_SHDN = 0V | - | 1 | - | 渭A |
| Operating Temperature | T_OP | Junction | -40 | - | 125 | 掳C |
Instructions for PM75CHA060
Power Supply Connection:
- Connect the input voltage (V_IN) to the power supply ensuring it is within the operating range of 4.5V to 60V.
Output Configuration:
- Adjust the output voltage (V_OUT) using the external resistor divider network according to the formula provided in the datasheet.
Frequency Setting:
- The switching frequency is fixed at 650kHz. Ensure this frequency is suitable for your application.
Quiescent and Shutdown Currents:
- Monitor the quiescent current which should be around 70渭A under no-load conditions.
- For shutdown, apply a low signal to the shutdown pin (V_SHDN) to reduce current consumption to approximately 1渭A.
Thermal Considerations:
- Operate within the junction temperature range of -40掳C to 125掳C to ensure reliable performance.
Output Current Capability:
- The device can deliver up to 3A continuously. Ensure proper heat sinking if operating near the maximum current limit.
Efficiency Monitoring:
- Check efficiency at typical operating conditions (e.g., 5V input, 3.3V output), aiming for around 90% efficiency.
Protection Features:
- Utilize built-in protection features such as overcurrent and thermal shutdown to safeguard the device against faults.