| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Blocking Voltage | V_RMS | - | 1400 | - | V | Repetitive Peak Reverse Voltage |
| Average Rectified Current | I_F(AV) | - | 15 | - | A | Average Rectified Output Current |
| Peak Recurrent Reverse Current | I_RM | - | 30 | - | A | Non-repetitive Peak Reverse Current |
| Junction Temperature | T_J | - | - | 175 | 掳C | Maximum Junction Temperature |
| Storage Temperature | T_STG | -65 | - | 175 | 掳C | Operating and Storage Temperature Range |
| Thermal Resistance | R_th | - | 1.2 | - | K/W | Junction to Ambient |
Instructions for Use:
- Mounting: Ensure the device is mounted on a suitable heat sink to manage the thermal resistance effectively.
- Voltage Handling: Do not exceed the maximum blocking voltage of 1400V to prevent damage.
- Current Limitation: Operate within the average rectified current limit of 15A to avoid overheating.
- Temperature Management: Keep the junction temperature below 175掳C. Monitor the ambient temperature to ensure it remains within the storage temperature range (-65掳C to 175掳C).
- Polarity Check: Verify correct polarity before applying voltage to avoid reverse breakdown.
- Surge Protection: Protect against transient overvoltages which can exceed the peak recurrent reverse current limit.
- Inspection: Regularly inspect the device for signs of wear or damage, especially in high-stress applications.