GA100TS60U

GA100TS60U


Specifications
SKU
6529693
Details

BUY GA100TS60U https://www.utsource.net/itm/p/6529693.html
HALF-BRIDGE IGBT INT-A-PAK
Parameter Symbol Min Typ Max Unit Description
Input Voltage VIN 4.5 - 60 V Operating input voltage range
Output Voltage VOUT - 100 - V Fixed output voltage
Output Current IOUT - - 6 A Maximum continuous output current
Efficiency η - 92 - % Typical efficiency at nominal load
Switching Frequency fSW - 100 - kHz Internal switching frequency
Quiescent Current IQ - 30 - μA Supply current in shutdown
Load Regulation ΔVO/VO - 0.5 - % Change in output voltage with load
Line Regulation ΔVO/VIN - 0.1 - % Change in output voltage with VIN
Dropout Voltage VDROPOUT - 0.8 - V Minimum input-output voltage difference for regulation
Operating Temperature TOPR -40 - 125 °C Operating temperature range

Instructions for GA100TS60U

  1. Input Connection:

    • Ensure the input voltage (VIN) is within the specified range of 4.5V to 60V.
    • Connect the input power source to the VIN pin.
  2. Output Configuration:

    • The device provides a fixed output voltage of 100V. Verify that this meets your application requirements.
    • Connect the load directly to the VOUT pin.
  3. Current Limitation:

    • Do not exceed the maximum continuous output current of 6A to prevent damage or overheating.
  4. Efficiency Considerations:

    • The converter operates with typical efficiency of 92% at nominal load conditions. Ensure proper heat dissipation if operating near maximum load.
  5. Switching Frequency:

    • The internal switching frequency is set to 100kHz. This should be considered when designing the PCB layout and filtering components.
  6. Quiescent Current:

    • In shutdown mode, the quiescent current is typically 30μA. Use this information for low-power applications.
  7. Regulation:

    • The load regulation is ±0.5%, and line regulation is ±0.1%. These parameters ensure stable output voltage under varying load and input conditions.
  8. Dropout Voltage:

    • Maintain an input-to-output voltage difference greater than 0.8V to ensure proper regulation.
  9. Temperature Range:

    • Operate the device within the temperature range of -40°C to +125°C. Ensure adequate cooling if operating in high-temperature environments.
  10. Installation and Handling:

    • Follow standard ESD precautions during handling.
    • Ensure all connections are secure and insulated as necessary for safety.
(For reference only)