CA3085

CA3085


Specifications
SKU
6539026
Details

BUY CA3085 https://www.utsource.net/itm/p/6539026.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage Vcc -18 +30 V
Input Offset Voltage Vio TA = 25°C -0.7 0 +0.7 mV
Input Bias Current Iib TA = 25°C -1 0 +1 nA
Input Offset Current Iio TA = 25°C -0.1 0 +0.1 nA
Slew Rate SR 0.3 V/μs
Bandwidth fT Open Loop 1.5 MHz
Output Short-Circuit Duration tsc >60 s

Instructions for CA3085

  1. Supply Voltage Setup:

    • Ensure the supply voltage is within the specified range of -18V to +30V.
  2. Input Connections:

    • Connect input signals ensuring that the input bias and offset currents are within the specified limits (-1nA to +1nA and -0.7mV to +0.7mV respectively).
  3. Output Configuration:

    • Be cautious with output connections as the device can withstand short circuits for more than 60 seconds, but prolonged exposure may affect performance.
  4. Operational Amplifier Usage:

    • For optimal performance, operate within the bandwidth limit (typically 1.5 MHz) and consider the slew rate of 0.3 V/μs when designing signal processing paths.
  5. Temperature Considerations:

    • The parameters provided are typically measured at 25°C. Performance can vary outside this temperature, so ensure proper thermal management in your design.
  6. Handling Static Electricity:

    • The CA3085 is sensitive to static electricity; use appropriate handling procedures to prevent damage.
  7. Circuit Protection:

    • Incorporate necessary protection circuits such as clamping diodes or resistors to protect against overvoltage conditions.

This table and set of instructions provide a comprehensive overview of the CA3085's key parameters and usage guidelines.

(For reference only)

View more about CA3085 on main site