LM158H

LM158H


Specifications
SKU
6540999
Details

BUY LM158H https://www.utsource.net/itm/p/6540999.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage Vcc Operating -16 +16 V
Input Offset Voltage VIO @ TA = 25°C -0.7 3 7 mV
Input Bias Current IB @ TA = 25°C 80 450 800 nA
Input Offset Current IOS @ TA = 25°C -10 45 100 nA
Large Signal Voltage Gain AV @ RF = 10kΩ, RL = 2kΩ 50 100 200 dB
Slew Rate SR @ RF = 10kΩ, RL = 2kΩ 0.5 1 V/μs
Output Short-Circuit Duration tSC Continuous Indefinite
Quiescent Current IQ @ TA = 25°C 0.4 0.7 0.8 mA
Common Mode Rejection Ratio CMRR @ TA = 25°C 60 85 90 dB
Power Supply Rejection Ratio PSRR @ TA = 25°C 60 85 90 dB

Instructions for Use:

  1. Power Supply:

    • The LM158H can operate from a single supply or split supplies.
    • For single-supply operation, the voltage range is typically 3V to 32V.
    • For dual-supply operation, the voltage range is ±1.5V to ±16V.
  2. Input Configuration:

    • Ensure that the input voltages remain within the common-mode input voltage range specified in the datasheet.
    • Avoid exceeding the maximum differential input voltage rating to prevent damage.
  3. Output Load:

    • The output can drive loads directly but consider using an external buffer for heavy loads to maintain performance and stability.
    • Keep the output load impedance within the recommended range to ensure proper operation.
  4. Stability Considerations:

    • Incorporate appropriate compensation capacitors if necessary to maintain stability, especially when driving capacitive loads or using high-gain configurations.
    • Follow the guidelines in the datasheet for frequency compensation to avoid oscillation.
  5. Thermal Management:

    • Ensure adequate heat dissipation, particularly at higher power levels or in confined spaces.
    • Monitor junction temperature to stay within safe operating limits.
  6. Handling Precautions:

    • Handle with care to avoid static discharge which can damage the internal components.
    • Store in a controlled environment away from excessive humidity and temperature extremes.
(For reference only)

View more about LM158H on main site