Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Supply Voltage | VCC | 2.5 | 3.3 | 5.5 | V | Power supply voltage |
Operating Current | ICC | - | 0.4 | 1 | mA | Current consumption in operating mode |
Output High Voltage | VOH | 2.4 | - | VCC | V | Output high level voltage |
Output Low Voltage | VOL | 0 | - | 0.4 | V | Output low level voltage |
Output Rise Time | tr | - | 10 | 20 | μs | Time for output to rise from 10% to 90% of final value |
Output Fall Time | tf | - | 10 | 20 | μs | Time for output to fall from 90% to 10% of final value |
Modulation Frequency | fM | 36 | 38 | 40 | kHz | Center frequency for IR signal |
Bandwidth | BW | 4.5 | - | 5.5 | kHz | Bandwidth around the center frequency |
Distance Range | DR | - | 20 | 50 | cm | Effective distance range for detection |
Instructions for TSOP38238
Power Supply Connection:
- Connect the VCC pin to a power supply within the specified range (2.5V to 5.5V).
- Ensure the GND pin is connected to the ground.
Signal Input:
- The TSOP38238 detects modulated infrared signals typically used in remote controls.
- Ensure that the IR signal is modulated at the center frequency (38kHz).
Output Signal:
- The output is active low, meaning it pulls low when an IR signal within the specified parameters is detected.
- Use a pull-up resistor on the output line if interfacing with logic circuits that require a defined high state.
Mounting Orientation:
- Mount the sensor with the photodetector facing the source of the IR signal for optimal performance.
Environmental Considerations:
- Avoid placing the sensor near heat sources or in direct sunlight to prevent interference and ensure reliable operation.
Testing:
- Test the sensor using a known IR remote control to verify functionality.
- Check the output with an oscilloscope or multimeter set to measure digital signals.