CLC014AJE

CLC014AJE


Specifications
SKU
6645327
Details

BUY CLC014AJE https://www.utsource.net/itm/p/6645327.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VDD Operating range 1.7 - 5.5 V
Input Voltage Range VIN With respect to GND -0.3 - VDD+0.3 V
Output Current IOUT Continuous, per output - 200 400 mA
Quiescent Current IQ All outputs high-Z - 80 120 μA
Shutdown Current ISD VEN = 0V - 1 5 μA
Propagation Delay tPD Typical, per channel - 6 10 ns
Channel-to-Channel Skew tSKEW Maximum, between any two channels - - 1 ns
Output Low Voltage VOL IO = 4mA, VDD = 5V - 0.4 0.8 V
Output High Voltage VOH IO = -4mA, VDD = 5V 4.2 - 5 V

Instructions for CLC014AJE:

  1. Power Supply:

    • Ensure the supply voltage (VDD) is within the operating range of 1.7V to 5.5V.
    • Connect the power supply to the VDD pin and ground to the GND pin.
  2. Input Signals:

    • Apply input signals within the range of -0.3V to VDD + 0.3V relative to GND.
    • Inputs can be driven by standard logic levels compatible with the supply voltage.
  3. Output Configuration:

    • The device supports up to 400mA output current per channel in continuous operation.
    • Outputs are high impedance (high-Z) when disabled or not actively driven.
  4. Quiescent and Shutdown States:

    • When all outputs are in high-Z state, the quiescent current should be around 80μA to 120μA.
    • To enter shutdown mode, set the enable pin (VEN) to 0V, reducing the current draw to 1μA to 5μA.
  5. Timing Considerations:

    • Account for a propagation delay of 6ns to 10ns for signal transitions.
    • Ensure that the maximum skew between any two channels does not exceed 1ns for synchronized operations.
  6. Output Levels:

    • For reliable low-level output, ensure the voltage does not exceed 0.8V at 4mA load.
    • For reliable high-level output, ensure the voltage is at least 4.2V at -4mA load when VDD is 5V.
  7. Handling and Storage:

    • Follow standard precautions for handling electrostatic sensitive devices (ESDs).
    • Store in a dry environment and follow manufacturer guidelines for long-term storage.
(For reference only)

View more about CLC014AJE on main site