Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Input Voltage | VIN | 42 | V | Maximum input voltage | ||
Output Voltage | VOUT | 1.2 | V | Regulated output voltage | ||
Continuous Current | ICONT | 30 | A | Continuous output current | ||
Peak Current | IPEAK | 36 | A | Peak output current | ||
Operating Temperature | TOPR | -40 | 125 | °C | Operating temperature range | |
Storage Temperature | TSTG | -65 | 150 | °C | Storage temperature range | |
Junction Temperature | TJ | 150 | °C | Maximum junction temperature | ||
Efficiency | η | 98 | % | Typical efficiency at full load |
Instructions for Use:
Power Supply Connection:
- Connect the input power supply to the VIN pin, ensuring it does not exceed the maximum input voltage of 42V.
- Ensure a stable and clean power source to avoid potential damage or performance degradation.
Output Configuration:
- The device provides a regulated output voltage of 1.2V. Verify that this meets your system requirements.
- For applications requiring different output voltages, consult the datasheet for external component configurations.
Current Handling:
- The device can handle a continuous current of up to 30A. For higher currents, consider the peak current capability of 36A but ensure thermal management is adequate.
- Avoid exceeding the continuous or peak current ratings to prevent overheating and potential failure.
Thermal Management:
- Operate within the specified operating temperature range (-40°C to 125°C) to ensure reliable performance.
- Implement proper heat sinking or cooling solutions if operating near the upper limit of the temperature range.
Storage and Handling:
- Store the device in environments where temperatures do not fall below -65°C or rise above 150°C.
- Handle with care to avoid electrostatic discharge (ESD) which can damage sensitive components.
Junction Temperature Monitoring:
- Keep the junction temperature below 150°C to maintain long-term reliability and performance.
- Regularly monitor the temperature, especially under heavy loads or in high ambient temperatures.
Efficiency Considerations:
- The device offers up to 98% efficiency under typical conditions. Optimize the circuit design around the device to maximize overall system efficiency.
For detailed specifications and advanced applications, refer to the manufacturer's datasheet and application notes.
(For reference only)View more about 30TPS16 on main site