Details
BUY MBRF20L100CT https://www.utsource.net/itm/p/6794079.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Repetitive Peak Reverse Voltage | VRRM | 100 | V | |||
| RMS Voltage | VRMS | 70.7 | V | |||
| Average Rectified Output Current (Tc = 100°C) | IO(AV) | f = 50/60 Hz, resistive load | 20 | A | ||
| Non-repetitive Surge Current | IFSM | tp = 8.3 ms sine half wave | 400 | A | ||
| Forward Voltage | VF | IF = 1 A | 0.7 | V | ||
| Reverse Current | IR | VRRM = 100 V | 100 | μA | ||
| Junction Operating Temperature | TJ | -55 | 150 | °C | ||
| Storage Temperature | TSTG | -65 | 150 | °C |
Instructions for MBRF20L100CT:
Handling and Storage:
- Store the device in a dry place within the temperature range of -65°C to 150°C.
- Handle with care to avoid mechanical damage.
Mounting:
- Ensure that the mounting surface is clean and free from contaminants.
- Apply appropriate thermal paste if necessary for heat dissipation.
Electrical Connections:
- Connect the device ensuring correct polarity.
- Use appropriately rated wires and connectors to handle the current and voltage specifications.
Operating Conditions:
- Operate within the specified temperature range (-55°C to 150°C).
- Do not exceed the maximum repetitive peak reverse voltage (100V) or average rectified output current (20A).
Surge Protection:
- For non-repetitive surge conditions, ensure the surge current does not exceed 400A for 8.3 ms sine half-wave pulses.
Testing:
- Verify all connections are secure and correct before applying power.
- Perform initial testing at reduced voltages/currents to ensure proper operation.
Maintenance:
- Regularly inspect connections and mounting surfaces for signs of wear or corrosion.
- Replace the device if any physical damage or performance degradation is observed.
View more about MBRF20L100CT on main site