Details
BUY FCPF7N60 https://www.utsource.net/itm/p/6794138.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Drain-Source Voltage | VDSS | - | - | 600 | V | Maximum drain-source voltage |
| Gate-Source Voltage | VGS | -15 | - | 15 | V | Maximum gate-source voltage |
| Continuous Drain Current | ID | - | 7 | - | A | Continuous drain current at TC = 25°C |
| Pulse Drain Current | IDM | - | 49 | - | A | Pulse drain current (t = 10 μs) |
| Total Device Dissipation | PD | - | - | 230 | W | Maximum power dissipation |
| Junction Temperature | TJ | -55 | - | 175 | °C | Operating junction temperature |
| Storage Temperature | TSTG | -55 | - | 150 | °C | Storage temperature range |
| Thermal Resistance, Junction to Case | RθJC | - | 0.48 | - | °C/W | Thermal resistance, junction to case |
Instructions for FCPF7N60
Handling and Storage:
- Store the device in a dry place away from direct sunlight.
- Handle with care to avoid damage to the leads and body.
Mounting:
- Ensure proper heat sinking when operating at high power levels to maintain junction temperature within limits.
- Use appropriate mounting hardware to secure the device.
Electrical Connections:
- Connect the gate to a low impedance source to minimize noise and ensure stable operation.
- Ensure all connections are secure and free of corrosion.
Operation:
- Do not exceed the maximum ratings specified in the table.
- Operate within the recommended operating conditions to ensure reliability and longevity.
Testing:
- When testing the device, use caution to avoid exceeding the maximum ratings, especially during pulse tests.
- Use protective equipment and follow safety guidelines when working with high voltages.
Disposal:
- Dispose of the device according to local regulations for electronic components.
For detailed specifications and additional information, refer to the datasheet provided by the manufacturer.
(For reference only)View more about FCPF7N60 on main site