MAX3232EUE

MAX3232EUE


Specifications
SKU
6800464
Details

BUY MAX3232EUE https://www.utsource.net/itm/p/6800464.html

Parameter Conditions Min Typ Max Unit
Operating Voltage (Vcc) - 3.0 5.5 - V
Output Current Per Line Driver - 10 - mA
Data Rate RS-232 Port - 120 - kbps
Input Capacitance - - 4 - pF
Output Capacitance - - 7 - pF
Power Supply Current All Lines Idle - 60 - μA
Shutdown Current In Shutdown Mode - 1 - μA

Instructions for MAX3232EUE

  1. Power Supply Connection:

    • Connect the VCC pin to a power supply between 3.0V and 5.5V.
    • Ensure the GND pin is connected to the system ground.
  2. RS-232 Interface Configuration:

    • Connect the T1OUT, R1IN, T2OUT, and R2IN pins to the corresponding lines of an RS-232 interface.
    • Use external capacitors as specified in the datasheet for level conversion.
  3. TTL/CMOS Interface Connection:

    • Connect the T1IN, R1OUT, T2IN, and R2OUT pins to TTL or CMOS logic circuits.
  4. Capacitor Installation:

    • Install 0.1μF capacitors between VCC and GND close to the device.
    • Place additional capacitors as required by the application, especially for proper operation of the charge pumps.
  5. Shutdown Mode:

    • To enter shutdown mode, pull the SHDN pin low. This reduces power consumption significantly.
    • Return the SHDN pin to high to resume normal operation.
  6. Data Transmission:

    • Ensure data rates do not exceed 120kbps to maintain reliable communication over RS-232.
  7. Handling Electrostatic Discharge (ESD):

    • The MAX3232EUE has built-in ESD protection but handle with care to avoid damage.
  8. Layout Considerations:

    • Keep signal traces short to minimize noise and crosstalk.
    • Follow recommended PCB layout guidelines for optimal performance.

Note: For detailed specifications and absolute maximum ratings, refer to the official MAX3232EUE datasheet provided by Maxim Integrated.

(For reference only)