Parameter | Description | Value | Unit |
---|---|---|---|
Operating Voltage | Supply voltage range for operation | 2.7 to 5.5 | V |
Operating Current | Typical current consumption | 0.4 | mA |
Output Type | Type of output signal | Open-drain | - |
Sensitivity | Magnetic field required for switching | 60 | Gauss |
Max Switching Frequency | Maximum frequency at which the device can switch | 100 | kHz |
Response Time | Time taken to respond to a change in magnetic field | 1 | ms |
Operating Temperature | Range of temperatures where it can operate | -40 to +85 | °C |
Storage Temperature | Range of temperatures for storage | -55 to +125 | °C |
Instructions for SA630D:
- Power Supply: Connect the VCC pin to a power supply within the operating voltage range (2.7V to 5.5V). Ensure the ground (GND) pin is connected to the system ground.
- Output Configuration: The output is open-drain, requiring a pull-up resistor between the output pin and VCC. Choose a resistor value that provides sufficient current for your application but minimizes power consumption.
- Magnetic Field Application: Position the sensor such that the magnetic field lines are perpendicular to the top surface of the package for optimal sensitivity.
- Signal Handling: Given the maximum switching frequency of 100kHz, ensure that the signal processing circuitry can handle this rate if rapid switching is expected.
- Temperature Considerations: Operate the device within its specified temperature range (-40°C to +85°C) to maintain reliability. For storage, keep within -55°C to +125°C.
- Installation: Mount the device in an area free from strong electromagnetic interference to avoid false triggering.