Details
BUY UPA1730G https://www.utsource.net/itm/p/6832528.html
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Input Voltage | V_IN | 2.7 | 5.5 | V | Operating input voltage range | |
Output Voltage | V_OUT | 3.3 | V | Fixed output voltage | ||
Quiescent Current | I_Q | 1.0 | μA | Supply current in operation | ||
Dropout Voltage | V_DROPOUT | 140 | mV | Voltage difference between VIN and VOUT | ||
Load Current | I_LOAD | 250 | 300 | mA | Maximum continuous output current | |
Shutdown Current | I_SHDN | 0.1 | μA | Supply current in shutdown mode | ||
Power Dissipation | P_DIS | 680 | mW | Maximum power dissipation at Tamb = 25°C | ||
Operating Temperature | T_OP | -40 | 85 | °C | Operating temperature range | |
Storage Temperature | T_STG | -65 | 150 | °C | Storage temperature range |
Instructions for UPA1730G
Power Supply Connection:
- Connect the input voltage (V_IN) within the specified range of 2.7V to 5.5V.
- Ensure the output capacitor is connected close to the output pin for stability.
Output Configuration:
- The UPA1730G provides a fixed output voltage of 3.3V. No external resistors are required for setting the output voltage.
Load Handling:
- The device can supply up to 300mA of load current continuously. Ensure the load does not exceed this limit to avoid overheating or damage.
Thermal Management:
- The maximum power dissipation is 680mW at an ambient temperature of 25°C. Proper heat sinking may be necessary for applications approaching this limit.
Shutdown Operation:
- To place the regulator in shutdown mode, pull the SHDN pin low. This reduces the supply current to approximately 0.1μA.
Capacitor Selection:
- Use capacitors with adequate ripple current ratings and ensure they have low ESR (Equivalent Series Resistance) for optimal performance and stability.
Operating and Storage Temperatures:
- Operate the device within the temperature range of -40°C to +85°C. Store the device between -65°C and +150°C.
Handling Precautions:
- Handle with care to prevent electrostatic discharge (ESD). Use appropriate ESD protection measures during installation and handling.
View more about UPA1730G on main site