UPA1730G

UPA1730G


Specifications
SKU
6832528
Details

BUY UPA1730G https://www.utsource.net/itm/p/6832528.html

Parameter Symbol Min Typ Max Unit Description
Input Voltage V_IN 2.7 5.5 V Operating input voltage range
Output Voltage V_OUT 3.3 V Fixed output voltage
Quiescent Current I_Q 1.0 μA Supply current in operation
Dropout Voltage V_DROPOUT 140 mV Voltage difference between VIN and VOUT
Load Current I_LOAD 250 300 mA Maximum continuous output current
Shutdown Current I_SHDN 0.1 μA Supply current in shutdown mode
Power Dissipation P_DIS 680 mW Maximum power dissipation at Tamb = 25°C
Operating Temperature T_OP -40 85 °C Operating temperature range
Storage Temperature T_STG -65 150 °C Storage temperature range

Instructions for UPA1730G

  1. Power Supply Connection:

    • Connect the input voltage (V_IN) within the specified range of 2.7V to 5.5V.
    • Ensure the output capacitor is connected close to the output pin for stability.
  2. Output Configuration:

    • The UPA1730G provides a fixed output voltage of 3.3V. No external resistors are required for setting the output voltage.
  3. Load Handling:

    • The device can supply up to 300mA of load current continuously. Ensure the load does not exceed this limit to avoid overheating or damage.
  4. Thermal Management:

    • The maximum power dissipation is 680mW at an ambient temperature of 25°C. Proper heat sinking may be necessary for applications approaching this limit.
  5. Shutdown Operation:

    • To place the regulator in shutdown mode, pull the SHDN pin low. This reduces the supply current to approximately 0.1μA.
  6. Capacitor Selection:

    • Use capacitors with adequate ripple current ratings and ensure they have low ESR (Equivalent Series Resistance) for optimal performance and stability.
  7. Operating and Storage Temperatures:

    • Operate the device within the temperature range of -40°C to +85°C. Store the device between -65°C and +150°C.
  8. Handling Precautions:

    • Handle with care to prevent electrostatic discharge (ESD). Use appropriate ESD protection measures during installation and handling.
(For reference only)

View more about UPA1730G on main site