Details
BUY BCM5248UA4KQM https://www.utsource.net/itm/p/6885516.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | 2.7 | - | 5.5 | V | Operating supply voltage range |
| Output Current | IOUT | - | 1.5 | 3.0 | A | Maximum output current |
| Quiescent Current | IQ | - | 2.5 | 4.5 | mA | Current consumption in quiescent state |
| Dropout Voltage | VDROPOUT | - | 300 | 600 | mV | Voltage difference between input and output when delivering rated current |
| Thermal Shutdown | TSD | - | - | 160 | °C | Temperature at which device shuts down to prevent damage |
| Operating Temperature | TOPR | -40 | - | 125 | °C | Ambient temperature range for operation |
Instructions:
- Power Supply Connection: Ensure the supply voltage (VCC) is within the specified range of 2.7V to 5.5V.
- Output Current Handling: Do not exceed the maximum output current of 3A to avoid damaging the component.
- Thermal Management: Monitor the operating temperature to ensure it does not exceed 125°C. The device will automatically shut down if the temperature reaches 160°C.
- Quiescent State: Be aware of the quiescent current, which can be up to 4.5mA, impacting overall system power consumption.
- Dropout Consideration: Take into account the dropout voltage, especially in low-voltage applications, as it can affect the efficiency and performance of your circuit.
- Installation Environment: Install in an environment where the ambient temperature stays within the operational range to ensure reliable performance.