Details
BUY H26M31001HPR https://www.utsource.net/itm/p/6922324.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VDD | Operating | 1.7 | 3.6 | V | |
| Output Current | IOUT | Continuous | 2.5 | 3 | A | |
| Switching Frequency | fSW | 400 | 2000 | kHz | ||
| Efficiency | η | @ 1A, 3.3V output | 88 | % | ||
| Quiescent Current | IQ | @ VIN = 3.3V | 90 | μA | ||
| Dropout Voltage | VDROPOUT | @ IOUT = 3A | 250 | mV | ||
| Load Transient Response | @ IOUT: 0A to 3A, 10μs | ±50 | mV | |||
| Line Transient Response | @ VIN: 2.5V to 3.6V, 1ms | ±30 | mV | |||
| Operating Temperature | Toper | -40 | 85 | °C | ||
| Storage Temperature | Tstg | -65 | 150 | °C |
Instructions for Use:
- Power Supply Connection: Ensure the input voltage (VDD) is within the specified range of 1.7V to 3.6V. Connect the power supply to the input pins carefully.
- Output Configuration: The device can provide a continuous output current up to 3A. Configure the output circuitry according to your load requirements.
- Thermal Considerations: The operating temperature range is from -40°C to 85°C. Ensure adequate heat dissipation if operating near the maximum temperature.
- Efficiency Optimization: For optimal efficiency, operate within the recommended conditions, especially around 1A with a 3.3V output.
- Transient Handling: The device is designed to handle load and line transients within specified limits. Verify that transient conditions do not exceed ±50mV for load and ±30mV for line changes.
- Storage Handling: When storing the device, ensure temperatures are between -65°C and 150°C to prevent damage.
- Quiescent Current Awareness: At a typical input voltage of 3.3V, the quiescent current is approximately 90μA. Factor this into overall power consumption calculations.
- Dropout Voltage Management: Be aware of the dropout voltage, which is about 250mV at full load, to avoid insufficient voltage regulation.