Details
BUY H5PS5162FFR-S6C https://www.utsource.net/itm/p/6922464.html
Parameter | Description | Value | Unit |
---|---|---|---|
Package | Package type and dimensions | WLCSP (16-ball) | |
Storage Temperature | Temperature range for storing the device without damage | -40 to +85 | °C |
Operating Temperature | Temperature range for operating the device | -25 to +85 | °C |
Supply Voltage | Range of supply voltage for operation | 1.7 to 3.6 | V |
Data Retention Time | Duration data is retained when power is off | 10 years | |
Access Time | Maximum time required for read/write operations | 70 | ns |
Capacity | Total storage capacity | 512 Mbit | |
Interface | Type of interface used for communication | SPI | |
Endurance | Number of program/erase cycles | 100,000 | cycles |
Instructions for H5PS5162FFR-S6C:
Power Supply Requirements:
- Ensure the supply voltage is within the specified range (1.7V to 3.6V). Using voltages outside this range can damage the device.
Operating Environment:
- Keep the operating temperature between -25°C and +85°C to ensure reliable performance.
- Store the device in an environment with temperatures ranging from -40°C to +85°C.
Programming and Erasing:
- The device supports up to 100,000 program/erase cycles. Avoid excessive cycling to prolong device life.
Data Access:
- The access time is 70 nanoseconds. Design your system timing to accommodate this delay for optimal performance.
Communication Interface:
- Use the SPI interface for communication. Refer to the datasheet for specific command sequences and protocol details.
Data Retention:
- Data will be retained for up to 10 years under normal operating conditions when power is off.
Handling Precautions:
- Handle the device with care to avoid electrostatic discharge (ESD), which can damage sensitive components.
- Follow proper soldering procedures to prevent thermal damage during installation.