Details
BUY SKM75GB176D https://www.utsource.net/itm/p/6994271.html
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Collector-Emitter Voltage | VCES | 1700 | V | |||
Emitter-Collector Voltage | VECES | -1700 | V | |||
Gate-Emitter Voltage | VGE | -20 | 20 | V | ||
Continuous Collector Current | IC | Tc = 25°C | 75 | A | ||
Tc = 100°C | 45 | A | ||||
Pulse Collector Current | ICM | tp = 10 ms, Rep Rate = 1/s | 300 | A | ||
Power Dissipation | Ptot | Tc = 25°C | 2000 | W | ||
Junction Temperature | Tj | -55 | 175 | °C | ||
Storage Temperature | Tstg | -55 | 150 | °C |
Instructions for SKM75GB176D:
Mounting and Handling:
- Ensure proper handling to avoid damage to the device.
- Use appropriate mounting hardware to ensure good thermal contact.
Electrical Connections:
- Verify all connections are secure and correctly wired according to circuit diagrams.
- Protect against electrostatic discharge (ESD) during installation.
Thermal Management:
- Ensure adequate heat sinking or cooling solutions are in place to manage power dissipation and maintain junction temperature within specified limits.
Operational Limits:
- Do not exceed the maximum ratings provided in the parameter table.
- Pay special attention to the continuous and pulse current ratings based on operating temperatures.
Testing and Inspection:
- Conduct thorough testing after installation to ensure the device is functioning as expected.
- Regularly inspect the device and its connections for any signs of wear or damage.
Storage and Environment:
- Store in a dry, cool environment away from direct sunlight and corrosive materials.
- Ensure the storage temperature remains within the specified range to prevent damage.
View more about SKM75GB176D on main site