Details
BUY IRAMS06UP60A-2 https://www.utsource.net/itm/p/6994639.html
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Drain-Source Voltage | VDSS | 60 | V | Maximum drain-source voltage | ||
Gate-Source Voltage | VGS | -10 | 10 | V | Maximum gate-source voltage | |
Continuous Drain Current | ID | 6.0 | A | Continuous drain current at TC = 25°C | ||
Pulse Drain Current | IDM | 36 | A | Pulse drain current (t = 10 μs, duty 1%) | ||
Power Dissipation | PD | 2.2 | W | Total power dissipation at TC = 25°C | ||
Junction Temperature | Tj | 175 | °C | Maximum junction temperature | ||
Storage Temperature | Tstg | -55 | 150 | °C | Operating storage temperature range |
Instructions for Use:
Installation:
- Ensure the ambient temperature does not exceed the maximum operating temperature of the device.
- Use appropriate heat sinks if continuous operation near the maximum drain current is expected.
Handling:
- Handle with care to avoid damage to the leads and body.
- Follow anti-static precautions to prevent damage from ESD (Electrostatic Discharge).
Operating Conditions:
- Do not exceed the specified maximum ratings for voltage, current, and temperature.
- For pulse applications, ensure that the pulse duration and frequency do not exceed the safe operating area.
Mounting:
- Mount the device in a way that ensures proper thermal management.
- Tighten screws to the recommended torque specifications provided by the manufacturer.
Testing:
- Perform initial testing under controlled conditions to verify correct operation.
- Monitor temperature and performance during operation to ensure reliability.
For detailed application notes and further information, refer to the datasheet provided by the manufacturer.
(For reference only)View more about IRAMS06UP60A-2 on main site