Details
BUY TT106N12KOF https://www.utsource.net/itm/p/6995096.html
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Input Voltage | VIN | 4.5 | - | 40 | V | Operating input voltage range |
Output Voltage | VOUT | - | 12 | - | V | Regulated output voltage |
Output Current | IOUT | - | 1 | 1.5 | A | Continuous output current |
Quiescent Current | IQ | - | 60 | - | μA | Supply current under no-load |
Dropout Voltage | VDROPOUT | - | 1.2 | - | V | Dropout voltage at rated load |
Line Regulation | LREG | - | 0.01 | - | %/V | Change in output voltage per volt of input change |
Load Regulation | LDREG | - | 0.05 | - | %/A | Change in output voltage per ampere of load change |
Ripple Rejection | RRPJCT | - | 70 | - | dB | Power supply rejection ratio at 120Hz |
Instructions for TT106N12KOF:
Input Connection:
- Connect the input voltage (VIN) to the positive terminal of the power source, ensuring it is within the specified range of 4.5V to 40V.
Output Connection:
- Connect the output terminals to the load requiring a regulated 12V supply. Ensure the load does not exceed the maximum output current of 1.5A continuously.
Ground Connection:
- Ensure a common ground connection between the input and output circuits to maintain stability and proper regulation.
Capacitor Recommendations:
- Place an input capacitor (typically 10μF) close to the VIN pin to filter out noise and transient spikes.
- Place an output capacitor (typically 22μF) close to the VOUT pin to stabilize the output voltage.
Thermal Considerations:
- Ensure adequate heat dissipation if operating near the maximum output current to prevent overheating. Use a heatsink if necessary.
Protection:
- The device includes built-in overcurrent and thermal shutdown protections. However, design external protection circuits as needed for specific applications.
Mounting:
- Follow standard surface-mount technology (SMT) procedures for mounting. Ensure solder joints are clean and free from excess solder to avoid short circuits.
Testing:
- After assembly, test the regulator under various load conditions to ensure it meets the required specifications.
View more about TT106N12KOF on main site