Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VDD Operating Range 1.6 - 5.5 V
Operating Temperature Topr -40 - 85 °C
Input Leakage Current IIH VDD = 5V - 1 - μA
Output Leakage Current IOL VSS = 0V - 1 - μA
High-Level Input Voltage VIH IOH = -1μA 2.0 - VDD V
Low-Level Input Voltage VIL IOL = 1μA 0 - 0.8 V
High-Level Output Voltage VOH IOH = -1μA VDD-0.4 - VDD-0.1 V
Low-Level Output Voltage VOL IOL = 1μA 0 - 0.4 V

Instructions for Use

  1. Power Supply:

    • Ensure the supply voltage (VDD) is within the operating range of 1.6V to 5.5V.
  2. Operating Environment:

    • The device is designed to operate within a temperature range from -40°C to +85°C.
  3. Input Signals:

    • For a valid high-level input, ensure the voltage (VIH) is between 2.0V and VDD.
    • For a valid low-level input, ensure the voltage (VIL) is between 0V and 0.8V.
  4. Output Signals:

    • When sourcing current (high-level output), the output voltage (VOH) should be between VDD-0.4V and VDD-0.1V.
    • When sinking current (low-level output), the output voltage (VOL) should not exceed 0.4V.
  5. Leakage Currents:

    • Keep in mind the maximum input leakage current (IIH) and output leakage current (IOL) are both specified as 1μA at their respective conditions.
  6. Handling and Storage:

    • Handle with care to avoid electrostatic discharge (ESD) damage. Store in recommended packaging in a dry environment.
  7. Application Considerations:

    • Refer to the specific application notes provided by the manufacturer for detailed guidance on circuit design and layout considerations.