Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | VDD | 4.75 | 5 | 5.25 | V | |
Reference Voltage | VREF | 0 | VDD | V | ||
Analog Input Voltage | VIN | 0 | VREF | V | ||
Output Data Rate | fCLK | 200 | kSPS | |||
Power Consumption | IDD | fCLK = 200kHz | 1.8 | mA | ||
Conversion Time | tCONV | 6.4 | μs | |||
Digital Output Formats | SPI, Microwire | |||||
Operating Temperature | Toper | -40 | 85 | °C | ||
Storage Temperature | Tstg | -65 | 150 | °C |
Instructions for ADC128S052QCMT:
Power Supply:
- Connect the VDD pin to a stable power supply between 4.75V and 5.25V.
- Ensure adequate decoupling capacitors are placed close to the power pins.
Reference Voltage Setup:
- The reference voltage (VREF) can be set by an external voltage or connected directly to VDD.
- For accurate conversions, use a stable and noise-free reference voltage.
Analog Input Configuration:
- Connect analog signals to the input channels within the range of 0V to VREF.
- Ensure signal integrity by using proper shielding and filtering if necessary.
Clock Configuration:
- Provide a clock signal to the CLK pin with a frequency up to 200kHz.
- The output data rate is dependent on this clock frequency.
Digital Interface:
- Configure the digital interface as SPI or Microwire according to your system requirements.
- Ensure correct protocol settings for communication.
Temperature Considerations:
- Operate the device within the temperature range of -40°C to +85°C for optimal performance.
- Store the device in temperatures ranging from -65°C to +150°C.
Conversion Initiation:
- Start conversions using the appropriate command through the digital interface.
- Allow sufficient time for conversion completion based on the specified conversion time.
Reading Conversion Results:
- After conversion, read the results from the digital output registers.
- Ensure that the read operation is synchronized with the conversion status.
Power Down Mode:
- Use the power-down mode to reduce power consumption when not actively converting.
- Reinitialize the device after exiting power-down mode.
Handling and Storage:
- Handle the device with care to avoid electrostatic discharge (ESD) damage.
- Store in recommended conditions to maintain reliability and longevity.