FF600R12ME4A_B11

FF600R12ME4A_B11


Specifications
SKU
7190761
Details

BUY FF600R12ME4A_B11 https://www.utsource.net/itm/p/7190761.html

Parameter Symbol Min Typ Max Unit Condition/Note
Rated Voltage VD - 1200 - V Maximum repetitive peak off-state voltage
Rated Current ID - 600 - A RMS value of output current
Total Dissipation PD - - 300 W At Tc = 25°C
Junction Temperature TJ -40 - 150 °C Operating junction temperature range
Storage Temperature TSTG -55 - 150 °C Storage temperature range
Gate Charge Qg - 85 - nC At VGE = ±15V, IC = 300A
Turn-on Time ton - 0.9 - μs At VGE = 15V, IC = 300A
Turn-off Time toff - 1.7 - μs At VGE = -10V, IC = 300A
Reverse Recovery Time trr - 1.2 - μs At IF = 300A, di/dt = 200A/μs

Instructions for FF600R12ME4A_B11

  1. Mounting and Handling:

    • Ensure the device is mounted on a suitable heatsink to maintain proper operating temperatures.
    • Handle with care to avoid damage to the terminals and package.
  2. Electrical Connections:

    • Connect the gate terminal (G) to the control circuit ensuring minimal inductance paths.
    • The anode (A) and cathode (K) connections should be made with adequate wire gauge to handle the rated current.
  3. Gate Drive Requirements:

    • Apply a positive gate-emitter voltage (+15V) for turn-on and a negative voltage (-10V) for turn-off to ensure reliable switching.
    • Use a gate resistor to limit gate current and provide damping.
  4. Thermal Management:

    • Monitor the junction temperature to prevent overheating. Ensure that the thermal resistance between the junction and ambient is minimized.
    • Consider derating the power dissipation at higher ambient temperatures.
  5. Overcurrent Protection:

    • Implement overcurrent protection mechanisms to safeguard against excessive currents which can lead to device failure.
  6. Testing and Verification:

    • Before full-scale operation, test the device under controlled conditions to verify performance parameters such as switching times and losses.
  7. Compliance and Standards:

    • Ensure that the application complies with relevant safety and electromagnetic compatibility (EMC) standards.
(For reference only)

View more about FF600R12ME4A_B11 on main site