Details
BUY ADS7807U https://www.utsource.net/itm/p/7248368.html
IC ADC 16BIT SAR 28SOIC
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Supply Voltage | VDD | 2.7 | - | 5.5 | V | Operating supply voltage |
| Analog Input Voltage | VIN | 0 | - | VDD | V | Range of analog input voltage |
| Digital Output Type | DO | - | CMOS | - | - | CMOS digital output |
| Conversion Time | tconv | - | 13 | - | μs | Typical conversion time |
| Resolution | N | - | 12 | - | bits | ADC resolution |
| Power Consumption | IDD | - | 800 | - | μA | Current consumption in active mode |
| Shutdown Current | ISD | - | 1 | - | μA | Current consumption in shutdown mode |
| Differential Nonlinearity | DNL | -1 | - | +1 | LSB | Differential nonlinearity |
| Integral Nonlinearity | INL | -2 | - | +2 | LSB | Integral nonlinearity |
Instructions for ADS7807U:
Power Supply Connection:
- Connect the VDD pin to a power supply within the range of 2.7V to 5.5V.
- Ensure a stable and clean power supply to minimize noise.
Analog Input Configuration:
- Connect the analog signal to be measured to the VIN pin.
- The input signal must be within the range of 0V to VDD.
Digital Interface Setup:
- Use the provided CMOS digital outputs for interfacing with microcontrollers or other digital systems.
- Ensure proper logic levels match those of the connected system.
Conversion Initiation:
- Trigger the conversion process according to the specific protocol defined by the device (e.g., via a start conversion pin or command).
- Wait for at least 13 microseconds for the conversion to complete.
Reading the Output:
- After the conversion is complete, read the 12-bit digital output from the digital output pins.
- Interpret the data as per the binary format specified in the datasheet.
Power Management:
- To reduce power consumption, use the shutdown feature by pulling the appropriate control pin low.
- In shutdown mode, the device consumes approximately 1 μA.
Calibration and Accuracy:
- Check the differential and integral nonlinearity specifications to understand potential errors.
- Apply calibration techniques if necessary to improve accuracy.
Handling and Storage:
- Follow standard ESD (Electrostatic Discharge) precautions when handling the component.
- Store in recommended environmental conditions to prevent damage.
View more about ADS7807U on main site