RS-485 Multi-Channel Transmitters/Receivers, Maxim Integrated
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | VCC | Operating | 2.7 | 5.5 | V | |
Output Current per Channel | IO | Per channel, continuous | 100 | mA | ||
Power Dissipation | PD | All channels on, TA = 25°C | 1.6 | W | ||
Operating Temperature | TOPR | Junction temperature range | -40 | 85 | °C | |
Storage Temperature | TSTG | Storage temperature range | -65 | 150 | °C |
Instructions for MAX3094EESE+
Power Supply Connection: Connect the supply voltage (VCC) within the specified range of 2.7V to 5.5V. Ensure stable power supply to avoid damage or malfunction.
Output Configuration: Each channel can provide up to 100mA of continuous current. Distribute the load evenly across channels if possible to optimize performance and heat dissipation.
Thermal Considerations: The device is designed to dissipate up to 1.6W when all channels are active at an ambient temperature of 25°C. Ensure adequate ventilation or cooling if operating in environments approaching the maximum power dissipation limits.
Temperature Range: Operate the device within the temperature range of -40°C to 85°C. For storage, ensure temperatures do not exceed -65°C to 150°C to prevent damage.
Installation and Handling: Handle with care to avoid static damage. Follow standard ESD precautions during installation and handling.
Application Notes: Refer to the datasheet for detailed application circuits and specific use cases to maximize the functionality and reliability of the MAX3094EESE+.