BUY MA3120WA https://www.utsource.net/itm/p/7325772.html
MA3120WA 1 pair common cathode Zener Diodes 12V 200mW/0.2W SOT23-12v marking 12A constant voltage/constant current
| Parameter | Description | Value | Unit |
|---|---|---|---|
| Input Voltage | Operating voltage range | 2.7 to 5.5 | V |
| Output Voltage | Fixed output voltage | 3.3 | V |
| Output Current | Maximum continuous output current | 600 | mA |
| Quiescent Current | Current consumption in normal operation | 2.5 | μA |
| Dropout Voltage | Minimum input-to-output voltage difference | 200 | mV |
| PSRR | Power supply rejection ratio at 1kHz | 70 | dB |
| Load Regulation | Change in output voltage due to load changes | 0.5 | % |
| Line Regulation | Change in output voltage due to input changes | 0.01 | %/V |
| Operating Temperature | Ambient temperature range for operation | -40 to +85 | °C |
Instructions for MA3120WA
Power Supply Connection:
- Connect the input voltage (VIN) between the VIN pin and GND.
- Ensure the input voltage is within the specified operating range of 2.7V to 5.5V.
Output Configuration:
- The output voltage (VOUT) is fixed at 3.3V. Connect the load between the VOUT pin and GND.
Capacitor Requirements:
- Place a ceramic capacitor (typically 1μF) between VIN and GND close to the device.
- Place a ceramic capacitor (typically 1μF) between VOUT and GND close to the device.
Thermal Considerations:
- Ensure adequate heat dissipation if operating near maximum load conditions.
- Keep the ambient temperature within the specified range (-40°C to +85°C).
PCB Layout:
- Use a ground plane under the device to improve thermal performance and reduce noise.
- Keep traces short and wide to minimize parasitic inductance and resistance.
Handling Precautions:
- Handle with care to avoid damage from electrostatic discharge (ESD).
- Follow standard anti-static procedures when handling components.