Fan Controller Interface 8-TDFN (2x3)
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Operating Supply Voltage | VDD | Normal operation | 2.7 | 5.5 | V | |
| Operating Temperature | TA | Commercial temperature range | -40 | 85 | °C | |
| Shutdown Current | ISD | VDD = 3.3V, THERM = GND | 1 | μA | ||
| Active Current | IOP | All outputs enabled, VDD = 3.3V | 300 | μA | ||
| Fan PWM Frequency | FPWM | Default setting | 25 | kHz | ||
| Remote Diode Accuracy | ΔT | VDD = 3.3V, -40°C to +125°C | -1 | +1 | °C | |
| Local Temperature Range | TL | -40 | 125 | °C | ||
| Remote Temperature Range | TR | -40 | 150 | °C |
Instructions for MAX31740ATA+
Power Supply Connection:
- Connect the VDD pin to a power supply within the operating voltage range (2.7V to 5.5V).
- Ensure the GND pin is connected to the system ground.
Temperature Sensing:
- Connect the remote diode inputs (TDI+, TDI-) to the external temperature sensor diode.
- For local temperature sensing, use the integrated sensor without additional connections.
Fan Control:
- Connect the PWM output to the fan control input.
- Adjust the PWM frequency if necessary using configuration settings.
Shutdown Mode:
- To enter shutdown mode, pull the THERM pin low.
- This reduces power consumption to approximately 1μA.
Configuration:
- Use the I2C interface to configure parameters such as temperature thresholds and PWM settings.
- Refer to the datasheet for specific I2C commands and register addresses.
Monitoring and Alert:
- Monitor temperature readings through the I2C interface.
- Set up alert thresholds to generate interrupts when temperatures exceed specified limits.
For detailed specifications and advanced configurations, refer to the official Maxim Integrated datasheet for the MAX31740ATA+.
(For reference only)View more about MAX31740ATA+ on main site