Details
BUY LT1039CSW https://www.utsource.net/itm/p/7671719.html
In Stock
Parameter | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Input Voltage Range | V+ to V- | 2.7 | 40 | V | |
Output Voltage | Adjustable | 1.24 | V | ||
Quiescent Current | VIN = 5V, IOUT = 0mA | 65 | μA | ||
Dropout Voltage | IOUT = 10mA | 0.6 | V | ||
Line Regulation | VIN = 10V to 30V | 0.01 | % | ||
Load Regulation | IOUT = 0mA to 15mA | 0.01 | % | ||
PSRR | f = 120Hz | 80 | dB | ||
Thermal Shutdown | Junction Temperature | 160 | °C | ||
Short-Circuit Current | VIN = 5V, VOUT = GND | 30 | mA |
Instructions for LT1039CSW:
Input Capacitor (CIN):
- Place a 0.1μF ceramic capacitor close to the input pins to ensure stability and reduce noise.
Output Capacitor (COUT):
- A 1μF ceramic capacitor is recommended for stable operation. Larger capacitors can be used for better transient response.
Feedback Resistor Network:
- Use the feedback resistors R1 and R2 to set the output voltage according to the formula: VOUT = 1.24V * (1 + R1/R2).
Thermal Considerations:
- Ensure adequate heat sinking if operating at high currents or in high ambient temperatures to prevent thermal shutdown.
Layout Recommendations:
- Keep the layout compact with short leads and wide traces for power and ground connections to minimize parasitic effects.
Power Supply Connections:
- Connect the input supply directly to the input pin, ensuring a solid ground connection to avoid instability.
Handling Static Electricity:
- Handle the device with care to avoid damage from static electricity; use proper ESD precautions.
Operating Temperature Range:
- The device is designed to operate within a junction temperature range of -40°C to 125°C.
These guidelines will help in achieving optimal performance from the LT1039CSW regulator.
(For reference only)View more about LT1039CSW on main site