Details
BUY FQL40N50 https://www.utsource.net/itm/p/7675856.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Collector-Emitter Voltage | V CES | - | - | 500 | V | Maximum voltage between collector and emitter |
| Collector Current | I C | - | - | 40 | A | Continuous collector current |
| Power Dissipation | P TOT | - | - | 210 | W | Total power dissipation |
| Junction Temperature | T J | - | - | 175 | °C | Maximum junction temperature |
| Storage Temperature | T STG | -55 | - | 150 | °C | Operating temperature range |
| Gate Charge | Q G | - | 96 | - | nC | Total gate charge |
| Turn-on Time | t on | - | 78 | - | ns | Turn-on delay time |
| Turn-off Time | t off | - | 94 | - | ns | Turn-off delay time |
Instructions for Use:
- Mounting: Ensure the FQL40N50 is securely mounted to a suitable heat sink to manage thermal resistance and maintain operational temperatures within specified limits.
- Handling: Handle with care to avoid damage to the gate terminal, which is sensitive to electrostatic discharge (ESD).
- Storage: Store in a dry environment within the temperature range specified to prevent damage.
- Operation: Do not exceed the maximum ratings listed in the parameter table to avoid damaging the device.
- Connections: Verify all connections are secure and correct before applying power. Incorrect wiring can lead to immediate failure.
- Testing: When testing, use appropriate safety measures and ensure that test conditions do not exceed the device's maximum ratings.
View more about FQL40N50 on main site