STA401A

STA401A


Specifications
SKU
8022241
Details

BUY STA401A https://www.utsource.net/itm/p/8022241.html

Parameter Symbol Conditions Min Typ Max Unit
Input Voltage V_IN Operating range 2.7 5.5 V
Output Voltage V_OUT Regulation 1.8 3.3 5.0 V
Quiescent Current I_Q No load 10 μA
Dropout Voltage V_DROPOUT I_OUT = 100mA 300 mV
Load Current I_OUT Continuous 250 300 mA
Shutdown Current I_SD V_SHDN = 0V 0.1 μA
Operating Temp. T_OP Junction -40 125 °C

Instructions for STA401A:

  1. Power Supply Connection: Connect the input voltage (V_IN) within the specified operating range of 2.7V to 5.5V.
  2. Output Configuration: Set the output voltage (V_OUT) as required using external resistors or by connecting it directly if fixed output versions are used.
  3. Quiescent Current Management: Ensure that the quiescent current is minimized when no load is connected to reduce power consumption.
  4. Load Handling: The device can handle up to a maximum continuous load current of 300mA. Ensure not to exceed this limit to avoid damage.
  5. Thermal Considerations: Operate within the temperature range of -40°C to 125°C to ensure reliable performance.
  6. Shutdown Functionality: Utilize the shutdown pin (V_SHDN) to reduce power consumption by setting it to 0V, which will lower the current draw to approximately 0.1μA.
  7. Capacitor Selection: Choose appropriate input and output capacitors to stabilize the voltage regulation and improve transient response.

For detailed design considerations and advanced applications, refer to the full datasheet provided by the manufacturer.

(For reference only)

View more about STA401A on main site