| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Blocking Voltage | V(BR)DSS | - | 600 | - | V | Maximum Drain-to-Source voltage |
| Continuous Drain Current | ID | - | 38 | - | A | Continuous Drain Current at Tc = 25°C |
| Pulse Drain Current | IDM | - | 170 | - | A | Pulse Drain Current (t=10μs, IGBT off-state) |
| Total Device Dissipation | PD | - | 490 | - | W | Total power dissipation at Tc = 25°C |
| Junction Temperature | TJ | - | - | 175 | °C | Maximum Junction Temperature |
| Storage Temperature Range | TSTG | -55 | - | 150 | °C | Operating temperature range |
| Gate Charge | Qg | 50 | - | 75 | nC | Total gate charge |
| Input Capacitance | Ciss | 4500 | - | 6000 | pF | Input capacitance |
| Output Capacitance | Coss | 480 | - | 600 | pF | Output capacitance |
| Reverse Transfer Capacitance | Crss | 120 | - | 160 | pF | Reverse transfer capacitance |
Instructions for FCD380N60E
Installation and Handling:
- Handle the device with care to avoid damage to the leads or body.
- Ensure that all connections are secure and correctly soldered.
Power Supply Considerations:
- Verify that the input voltage does not exceed the maximum blocking voltage (V(BR)DSS).
- Ensure proper heat sinking if operating near maximum power dissipation (PD).
Thermal Management:
- Monitor junction temperature (TJ) to ensure it stays within safe limits.
- Use appropriate cooling methods such as heatsinks or fans if necessary.
Electrical Connections:
- Connect the drain terminal to the high-side of the load.
- Connect the source terminal to the low-side of the load or ground.
- Apply gate signals carefully to avoid exceeding the gate-source voltage ratings.
Testing and Troubleshooting:
- Test the device under controlled conditions before integrating into a larger system.
- If issues arise, check connections, voltages, and thermal management first.
Safety Precautions:
- Always adhere to safety guidelines when working with high voltages.
- Ensure proper insulation and grounding to prevent electrical hazards.
View more about FCD380N60E on main site