Details
BUY MST720A-LF https://www.utsource.net/itm/p/8149736.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VDD | Operating | 2.7 | 5.5 | V | |
| Output Current | IOUT | Continuous | 300 | mA | ||
| Operating Temp. | Toper | Junction | -40 | 85 | °C | |
| Storage Temp. | Tstg | -65 | 150 | °C | ||
| Quiescent Current | IQ | VDD = 5V, no load | 10 | μA | ||
| Load Regulation | 1mA to 300mA | 0.5 | % | |||
| Line Regulation | 2.7V to 5.5V | 0.1 | % |
Instructions for MST720A-LF
Power Supply Connection:
- Connect the positive terminal of the power supply to the VDD pin.
- Connect the negative terminal (GND) of the power supply to the GND pin.
Load Connection:
- Connect the load between the OUT pin and GND pin.
Capacitors:
- It is recommended to place a 1μF ceramic capacitor between VDD and GND close to the device for stability.
- A 10μF tantalum capacitor can be placed between OUT and GND if needed for additional filtering.
Operating Environment:
- Ensure that the operating temperature range does not exceed -40°C to +85°C to avoid performance degradation or damage.
Handling Precautions:
- Handle with care as static electricity can damage the component. Use proper ESD protection measures.
- Avoid exposing the device to environments exceeding the storage temperature limits (-65°C to +150°C).
Mounting:
- Follow the manufacturer's guidelines for PCB layout and mounting to ensure optimal performance and thermal management.
View more about MST720A-LF on main site