BUY LT5575EUF#PBF https://www.utsource.net/itm/p/8192630.html
New and original
Parameter | Description | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Supply Voltage | Operating voltage range | 4.75 | 5.25 | V | |
Power Dissipation | Maximum power dissipation | 1000 | mW | ||
Operating Temperature | Junction temperature range | -40 | 85 | °C | |
Input RF Frequency | Frequency range for optimal performance | 698 | 3800 | MHz | |
Gain | Conversion gain | 22 | dB | ||
NF | Noise figure | 11 | dB | ||
IIP3 | Third-order input intercept point | -10 | dBm | ||
OIP3 | Third-order output intercept point | 12 | dBm | ||
Isolation (LO to RF) | Isolation between LO and RF ports | 35 | dB | ||
Isolation (LO to IF) | Isolation between LO and IF ports | 45 | dB | ||
LO Power | Required local oscillator power | 0 | +3 | dBm |
Instructions:
- Power Supply Requirements: Ensure the supply voltage is within the specified range of 4.75V to 5.25V to avoid damage or improper operation.
- Temperature Considerations: Operate the device within the temperature range of -40°C to +85°C to ensure reliable performance.
- Frequency Range: Use the device within the frequency range of 698 MHz to 3800 MHz for optimal performance.
- Gain Adjustment: The conversion gain is typically around 22 dB. Adjust external components if a different gain level is required.
- Noise Figure Management: With a typical noise figure of 11 dB, consider this in system-level noise budget calculations.
- Intercept Points: Be mindful of the third-order intercept points (IIP3 and OIP3) when designing the circuit to minimize distortion.
- Isolation Levels: Ensure that isolation levels meet the design requirements to prevent unwanted signal interactions.
- Local Oscillator Power: Provide the correct LO power level (+0 to +3 dBm) as specified to achieve the best performance.
For detailed specifications and more advanced usage, refer to the datasheet provided by the manufacturer.
(For reference only)View more about LT5575EUF#PBF on main site