IRGPC40UD2

IRGPC40UD2


Specifications
SKU
8284081
Details

BUY IRGPC40UD2 https://www.utsource.net/itm/p/8284081.html

Parameter Symbol Min Typ Max Unit Description
Collector-Emitter Voltage V CES - - 600 V Maximum collector-emitter voltage
Emitter-Collector Voltage V ECS - - 600 V Maximum emitter-collector voltage
Gate-Emitter Voltage V GES -15 - 15 V Maximum gate-emitter voltage
Continuous Collector Current I CES - 40 - A Continuous collector current
Pulse Collector Current I CESM - 80 - A Non-repetitive peak pulse current
Power Dissipation P TOT - - 250 W Total power dissipation
Junction Temperature T J - - 150 °C Maximum junction temperature
Storage Temperature T STG -55 - 150 °C Operating and storage temperature range

Instructions for Use:

  1. Mounting and Handling:

    • Handle the device carefully to avoid damage to the leads or body.
    • Ensure proper heat sinking if operating near maximum power dissipation.
  2. Electrical Connections:

    • Connect the gate lead directly to the control circuit to minimize stray inductance.
    • Use short, heavy gauge wires for the collector and emitter connections to reduce inductance and improve switching performance.
  3. Thermal Management:

    • Monitor the junction temperature to ensure it does not exceed the maximum allowable value.
    • Provide adequate cooling (e.g., heatsinks or forced air cooling) to maintain safe operating temperatures.
  4. Overcurrent Protection:

    • Implement overcurrent protection to safeguard against excessive currents that can cause thermal runaway.
  5. Gate Drive Requirements:

    • Ensure the gate drive circuitry provides sufficient voltage and current to switch the device on and off reliably.
    • Avoid exceeding the maximum gate-emitter voltage ratings.
  6. Safe Operating Area (SOA):

    • Refer to the SOA graph provided in the datasheet to ensure operation within safe limits for various duty cycles and pulse durations.
  7. Storage Conditions:

    • Store in a dry, cool environment to prevent damage from moisture or extreme temperatures.
  8. Compliance and Standards:

    • Ensure that all applications comply with relevant safety and regulatory standards.

For detailed specifications and additional information, refer to the manufacturer's datasheet.

(For reference only)

View more about IRGPC40UD2 on main site