| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Operating Voltage | VDD | 1.62 | 5.5 | V | ||
| Threshold Voltage (Typ) | VIT | Rising | 1.23 | 1.37 | V | |
| Hysteresis Voltage | VHYS | 0.15 | 0.25 | V | ||
| Output Low Voltage | VOL | IO = 1 mA | 0.08 | 0.4 | V | |
| Output High Voltage | VOH | IO = -1 mA | 2.4 | VDD-0.5 | V | |
| Response Time | tD | VIN = 0.8V to 2.0V, CL = 10 pF | 1.2 | 3.5 | μs | |
| Supply Current | ICC | 0.6 | 1.2 | 2.0 | μA |
Instructions for TPS3808G01DBVR
Power Supply Requirements:
- Ensure the supply voltage (VDD) is within the range of 1.62V to 5.5V.
Threshold and Hysteresis:
- The device triggers an output change when the input voltage crosses the threshold voltage (VIT).
- A hysteresis voltage (VHYS) ensures stable operation by providing a difference between the rising and falling thresholds.
Output Levels:
- When active, the output low voltage (VOL) should be less than 0.4V.
- When inactive, the output high voltage (VOH) should be at least 2.4V or up to VDD - 0.5V.
Timing Considerations:
- The response time (tD) from input change to output response is typically between 1.2μs and 3.5μs with a 10pF load capacitor.
Supply Current:
- The supply current (ICC) can vary from 0.6μA to 2.0μA depending on operating conditions.
Handling Precautions:
- Handle the device with care to avoid electrostatic discharge (ESD) damage.
- Follow recommended PCB layout guidelines for optimal performance.
Application Specific Notes:
- Refer to the datasheet for detailed application notes and specific use cases to ensure proper integration into your design.