Details
BUY L6278AC https://www.utsource.net/itm/p/8840891.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | Vcc | Operating | 4.5 | - | 20 | V |
| Output Current per Phase | Iout | Continuous | - | 1.5 | 2.0 | A |
| Peak Output Current | Ipeak | - | 3.0 | 3.5 | A | |
| Thermal Shutdown | TSD | 160 | - | - | °C | |
| Operating Temperature | Topr | Storage | -40 | - | 85 | °C |
| Standby Current | Isb | Vcc = 5V | - | 10 | - | μA |
| Power Dissipation | Pd | Ta = 25°C | - | 1.25 | - | W |
Instructions for L6278AC
Power Supply Connection:
- Connect the supply voltage (Vcc) within the range of 4.5V to 20V.
- Ensure proper decoupling capacitors are placed close to the power pins to maintain stability.
Current Limiting:
- The device can handle a continuous output current up to 1.5A per phase, with peak currents up to 3.5A.
- Use external resistors or components as necessary to limit current and protect the device from damage.
Thermal Management:
- Monitor the operating temperature to ensure it does not exceed 85°C.
- If the junction temperature reaches approximately 160°C, thermal shutdown will activate to protect the device.
Standby Mode:
- In standby mode, the current consumption is minimal (around 10μA at 5V), which helps in reducing power consumption during inactive periods.
Heat Dissipation:
- Ensure adequate heat dissipation to keep the power dissipation within safe limits, especially when operating near the maximum allowable temperatures.
Layout Considerations:
- Follow recommended PCB layout guidelines to minimize electromagnetic interference and improve performance.
- Keep signal traces short and direct, especially for high-frequency signals.
Safety Precautions:
- Always use appropriate safety measures when handling and testing electronic components.
- Ensure all connections are secure and correct to prevent damage to the device or surrounding components.
View more about L6278AC on main site