Details
BUY CD74HC164M https://www.utsource.net/itm/p/9010209.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | Operating | 2.0 | 6.0 | V | |
| Input Low Voltage | VIL | IIL = 1.0mA | 0.8 | V | ||
| Input High Voltage | VIH | IIH = -0.4mA | 2.0 | V | ||
| Output Low Voltage | VOL | IO = -4.0mA | 0.1 | V | ||
| Output High Voltage | VOH | IO = 1.6mA | 2.4 | V | ||
| Propagation Delay Time | tpd | VCC = 5V, TA = 25°C | 17 | ns | ||
| Power Dissipation | PD | 100 | mW | |||
| Operating Temperature | TA | -40 | 85 | °C |
Instructions for CD74HC164M
Power Supply Connections:
- Connect VCC to the positive supply voltage (2.0V to 6.0V).
- Connect GND to the ground.
Input Handling:
- Ensure input voltages are within specified limits (VIL and VIH) to avoid incorrect logic states.
- Use appropriate pull-up or pull-down resistors if necessary to stabilize inputs.
Output Considerations:
- Outputs can source or sink current up to the specified limits. Ensure load currents do not exceed these values to prevent damage.
- When driving capacitive loads, consider adding series resistors to limit peak currents.
Propagation Delay:
- Account for propagation delay in timing calculations, especially in high-speed applications.
Temperature Range:
- Operate the device within the specified temperature range (-40°C to 85°C) to ensure reliable operation.
Storage and Handling:
- Store in a dry environment and handle with care to prevent electrostatic discharge (ESD) damage. Use proper ESD protection measures when handling the device.
Mounting and PCB Layout:
- Follow recommended PCB layout guidelines to minimize noise and ensure optimal performance. Keep power and ground planes robust to provide stable power distribution.
Testing:
- Verify all connections before applying power. Test under typical operating conditions to ensure correct functionality.
View more about CD74HC164M on main site