Details
BUY CD74HC4053PWR https://www.utsource.net/itm/p/9010788.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | 2.0 | 6.0 | V | Operating supply voltage range | |
| Output Voltage (High) | VOH | VCC-0.1 | V | Output high level voltage | ||
| Output Voltage (Low) | VOL | 0.1 | V | Output low level voltage | ||
| Input Current | IIH/IL | -1 | 1 | μA | Input current at logic levels | |
| Propagation Delay Time | tpd | 7 | ns | Propagation delay time | ||
| Power Dissipation | PD | 500 | mW | Maximum power dissipation | ||
| Operating Temperature | Toper | -40 | 85 | °C | Operating temperature range | |
| Storage Temperature | Tstg | -65 | 150 | °C | Storage temperature range |
Instructions for CD74HC4053PWR
Supply Voltage: Ensure the supply voltage is within the specified range of 2.0V to 6.0V to prevent damage or unreliable operation.
Signal Levels:
- For reliable operation, ensure that input signals are within the specified voltage levels relative to the supply voltage.
- The output voltage levels should not exceed VCC-0.1V when high and should be at least 0.1V when low.
Current Handling:
- Keep input currents within the limits to avoid damaging the inputs.
- Be aware of the maximum power dissipation limit to ensure the device does not overheat during operation.
Propagation Delay:
- Account for the propagation delay in timing-critical applications to ensure proper signal synchronization.
Temperature Considerations:
- Operate the device within the specified operating temperature range to ensure reliable performance.
- Store the device within the storage temperature range to prevent physical damage.
Handling Precautions:
- Handle with care to avoid electrostatic discharge (ESD), which can damage sensitive components.
- Follow manufacturer guidelines for soldering and mounting to ensure optimal performance and longevity.
View more about CD74HC4053PWR on main site