BUY CD74HC4316E https://www.utsource.net/itm/p/9046686.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | 2.0 | 6.0 | V | ||
| Input Low Voltage | VIL | IL = 1 mA | 0.8 | V | ||
| Input High Voltage | VIH | IH = -0.4 mA | 2.0 | V | ||
| Output Low Voltage | VOL | IOL = 4 mA | 0.1 | 0.4 | V | |
| Output High Voltage | VOH | IOH = -0.4 mA | 2.4 | 5.0 | V | |
| Propagation Delay Time | tp | VCC = 5V, TA = 25°C | 7 | 16 | ns | |
| Power Dissipation | PD | Continuous Operation | 100 | mW | ||
| Operating Temperature | TOP | -40 | 85 | °C |
Instructions for CD74HC4316E:
Supply Voltage (VCC):
- Ensure the supply voltage is within the range of 2.0V to 6.0V to avoid damage or improper operation.
Input Signals:
- For reliable operation, input signals should be within the specified low and high voltage levels.
- Input voltages exceeding VCC or below GND can cause latch-up or damage the device.
Output Signals:
- The output voltage levels are dependent on the load current. Ensure that the load does not exceed the maximum output current ratings.
Propagation Delay:
- Timing critical applications should account for the propagation delay, which can vary with temperature and supply voltage.
Power Dissipation:
- Do not exceed the maximum power dissipation limit. Use appropriate heat sinking if necessary.
Operating Temperature:
- The device is designed to operate within the temperature range of -40°C to 85°C. Operation outside this range may affect performance and reliability.
Handling Precautions:
- This device is sensitive to electrostatic discharge (ESD). Handle with care using ESD protection measures.
Mounting:
- Ensure proper mounting and soldering techniques to prevent thermal and mechanical stresses that could damage the device.