Details
BUY DS90LV031ATM https://www.utsource.net/itm/p/9117167.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | 2.7 | 5.5 | V | Operating supply voltage range | |
| Differential Input Voltage | VIN | -0.3 | 0.3 | V | Maximum differential input voltage | |
| Output High Voltage | VOH | 2.4 | 5.0 | V | Minimum output high voltage at IOH = 4mA | |
| Output Low Voltage | VOL | 0 | 0.4 | V | Maximum output low voltage at IOL = 8mA | |
| Propagation Delay | tpd | 1.9 | ns | Propagation delay time | ||
| Skew | tskew | 0.4 | ns | Channel-to-channel skew | ||
| Power-down Current | IDD | 1 | 5 | μA | Quiescent supply current in power-down mode | |
| Operating Temperature | Toper | -40 | 85 | °C | Operating temperature range | |
| Storage Temperature | Tstg | -65 | 150 | °C | Storage temperature range |
Instructions for DS90LV031ATM:
Power Supply Connection: Connect the VCC pin to a stable power supply within the specified range (2.7V to 5.5V). Ensure proper decoupling capacitors are placed close to the VCC pin to minimize noise and transients.
Signal Integrity: To maintain signal integrity, use controlled impedance traces for differential pairs and ensure lengths are matched as closely as possible to reduce skew.
Power Down Mode: To enter power-down mode, set the appropriate control line to the specified level. This reduces power consumption significantly but disables data transmission.
Temperature Considerations: The device is designed to operate within an ambient temperature range of -40°C to 85°C. Ensure adequate heat dissipation if operating near the upper limit.
Input Protection: Be cautious not to exceed the maximum differential input voltage (-0.3V to 0.3V) to prevent damage to the device.
Propagation Delay and Skew: For timing-critical applications, account for the propagation delay and channel-to-channel skew in your design to ensure reliable data transmission.
Storage Conditions: When storing the device, keep it within the storage temperature range (-65°C to 150°C) to avoid degradation of performance or reliability.
Handling Precautions: Handle with care to avoid electrostatic discharge (ESD), which can damage sensitive components. Use proper ESD protection practices during handling and installation.