| Parameter | Description | Symbol | Min | Typ | Max | Unit | 
|---|---|---|---|---|---|---|
| Operating Voltage | Supply voltage range | VDD | 2.0 | - | 5.5 | V | 
| Operating Temperature | Industrial temperature range | Toper | -40 | - | +85 | °C | 
| Standby Current | Supply current in standby mode | ISB | - | 350 | 700 | nA | 
| Operating Current | Supply current during operation | IOP | - | 260 | 400 | μA | 
| Clock Accuracy | Monthly accuracy at 25°C | Δf/f | - | ±2.0 | - | ppm | 
| Output Frequency | Square wave output frequency options | fOUT | - | - | - | Hz | 
| Output Duty Cycle | Square wave output duty cycle | DUTY | - | 50 | - | % | 
Instructions for PCF8563T/F4
- Power Supply Connection: - Connect VDD to the positive supply voltage (2.0V to 5.5V).
- Connect VSS to ground.
 
- Clock Input Configuration: - Connect a 32.768 kHz crystal between X1 and X2 pins for accurate timekeeping.
- Ensure proper load capacitance is provided as specified by the crystal datasheet.
 
- I2C Bus Interface: - The device communicates via the I2C bus using SDA and SCL lines.
- Ensure pull-up resistors are connected to the SDA and SCL lines to VDD.
 
- Register Configuration: - Use the control registers to set up alarms, square wave outputs, and other functionalities.
- Refer to the datasheet for specific register addresses and bit configurations.
 
- Time Setting: - Set the initial time by writing to the appropriate timekeeping registers.
- Time can be read from these registers as needed.
 
- Alarm Setup: - Configure alarm settings through the ALMx_H and ALMx_L registers (where x is the alarm number).
- Enable the corresponding interrupt if an interrupt signal is required upon alarm match.
 
- Square Wave Output: - Select the desired output frequency (1Hz, 2kHz, 4kHz, or 8kHz) using the SQWE and RS bits.
- Enable the square wave output function to use the SQW/OUT pin.
 
- Power Management: - Utilize the power management features to reduce power consumption when not actively using the RTC functions.
 
- Handling and Storage: - Store in a dry environment to prevent moisture damage.
- Handle with care to avoid static discharge which can damage the sensitive electronic components.
 