24C01-6

24C01-6


Specifications
SKU
9785310
Details

BUY 24C01-6 https://www.utsource.net/itm/p/9785310.html

Parameter Description Value
Device Type Serial EEPROM 24C01-6
Organization I2C Interface
Memory Size 1K bit (128 bytes)
Operating Voltage VCC 1.8V to 5.5V
Operating Current Active Current 1mA max
Standby Current Standby Current 1μA max
Write Cycle Time Typical Write Cycle Time 5ms max
Data Retention Data Retention Time 200 years min
Write Cycles Endurance for Each Memory Cell 1,000,000
Operating Temp. Operating Temperature Range -40°C to 85°C
Package Package Type SOIC-8

Instructions:

  1. Power Supply: Connect the VCC pin to a power supply within the operating voltage range (1.8V to 5.5V). Ground the GND pin.
  2. I2C Interface Setup:
    • Connect SDA (Data Line) and SCL (Clock Line) to the respective lines of the microcontroller or host system.
    • Ensure pull-up resistors are connected to both SDA and SCL lines.
  3. Address Configuration:
    • The device has a fixed I2C address unless A0, A1, A2 pins are used for address selection.
  4. Write Operation:
    • Start condition on the I2C bus.
    • Send the control byte (device address + write command).
    • Send the memory address where data is to be written.
    • Transmit the data byte(s) to be written.
    • Stop condition on the I2C bus.
    • Wait for at least 5ms before starting another write cycle to allow completion of the previous write operation.
  5. Read Operation:
    • Start condition on the I2C bus.
    • Send the control byte (device address + write command).
    • Send the memory address from which data is to be read.
    • Repeated start condition.
    • Send the control byte (device address + read command).
    • Read the data byte(s).
    • Send an NACK after the last byte you want to read.
    • Stop condition on the I2C bus.
  6. Handling:
    • Ensure that the device is not exposed to voltages outside its specified operating range.
    • Avoid exceeding the maximum operating temperature and humidity levels to prevent damage.
  7. Storage:
    • Store in a dry environment to avoid moisture damage.
(For reference only)

View more about 24C01-6 on main site