| Parameter | Symbol | Conditions | Min | Typ | Max | Unit | 
|---|---|---|---|---|---|---|
| Supply Voltage | VDD | Operating | 4.5 | 5.0 | 5.5 | V | 
| Standby Current | ISB | VDD = 5V | - | 1 | - | μA | 
| Operating Current | IOP | TA = 25°C, fCLK = 3MHz | 1 | 2 | 3 | mA | 
| Output Low Voltage | VOL | IOH = 4mA | 0.2 | - | 0.4 | V | 
| Output High Voltage | VOH | IOL = -4mA | 4.6 | - | 4.8 | V | 
| Propagation Delay Time | tpd | VI = VIL to VIH, fCLK | 50 | - | 100 | ns | 
| Storage Temperature Range | Tstg | -65 | - | 150 | °C | |
| Operating Temperature Range | Topr | 0 | - | 70 | °C | 
Instructions for M58725P
- Power Supply Requirements: - Ensure the supply voltage (VDD) is within the range of 4.5V to 5.5V for reliable operation.
 
- Current Consumption: - Monitor the standby current (ISB) which should typically be around 1μA at VDD = 5V.
- The operating current (IOP) can range from 1mA to 3mA depending on the clock frequency and temperature conditions.
 
- Output Voltage Levels: - When the output is low (VOL), ensure it does not exceed 0.4V under a load current of 4mA.
- When the output is high (VOH), ensure it remains above 4.6V under a load current of -4mA.
 
- Timing Characteristics: - The propagation delay time (tpd) should be between 50ns and 100ns for proper signal transmission.
 
- Temperature Specifications: - Store the device in an environment where the temperature ranges from -65°C to 150°C.
- Operate the device within a temperature range of 0°C to 70°C for optimal performance.
 
- Handling Precautions: - Handle with care to avoid damage due to electrostatic discharge (ESD).
- Follow standard electronic component handling guidelines to prevent damage during installation and use.
 