| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VDD | Operating | 4.5 | 5.0 | 5.5 | V |
| Standby Current | ISB | VDD = 5V | - | 1 | - | μA |
| Operating Current | IOP | TA = 25°C, fCLK = 3MHz | 1 | 2 | 3 | mA |
| Output Low Voltage | VOL | IOH = 4mA | 0.2 | - | 0.4 | V |
| Output High Voltage | VOH | IOL = -4mA | 4.6 | - | 4.8 | V |
| Propagation Delay Time | tpd | VI = VIL to VIH, fCLK | 50 | - | 100 | ns |
| Storage Temperature Range | Tstg | -65 | - | 150 | °C | |
| Operating Temperature Range | Topr | 0 | - | 70 | °C |
Instructions for M58725P
Power Supply Requirements:
- Ensure the supply voltage (VDD) is within the range of 4.5V to 5.5V for reliable operation.
Current Consumption:
- Monitor the standby current (ISB) which should typically be around 1μA at VDD = 5V.
- The operating current (IOP) can range from 1mA to 3mA depending on the clock frequency and temperature conditions.
Output Voltage Levels:
- When the output is low (VOL), ensure it does not exceed 0.4V under a load current of 4mA.
- When the output is high (VOH), ensure it remains above 4.6V under a load current of -4mA.
Timing Characteristics:
- The propagation delay time (tpd) should be between 50ns and 100ns for proper signal transmission.
Temperature Specifications:
- Store the device in an environment where the temperature ranges from -65°C to 150°C.
- Operate the device within a temperature range of 0°C to 70°C for optimal performance.
Handling Precautions:
- Handle with care to avoid damage due to electrostatic discharge (ESD).
- Follow standard electronic component handling guidelines to prevent damage during installation and use.