Parameter Symbol Min Typ Max Unit Conditions
Drain-Source Voltage VDS 60 V
Gate-Source Voltage VGS -10 20 V
Continuous Drain Current ID 8.5 A TC = 25°C
Pulse Drain Current IDM 47 A TP = 10ms, TC = 25°C
RDS(on) at VGS = 4.5V RDS(on) 11 ID = 8.5A, TC = 25°C
RDS(on) at VGS = 10V RDS(on) 7.5 ID = 8.5A, TC = 25°C
Input Capacitance Ciss 3900 pF VDS = 10V, VGS = 0V to 10V
Output Capacitance Coss 1100 pF VDS = 10V, VGS = 0V
Reverse Transfer Capacitance Crss 1100 pF VDS = 10V, VGS = 0V to 10V
Total Gate Charge QG 72 nC VGS = 10V, IDS = 8.5A

Instructions for Use:

  1. Power Supply and Heat Dissipation:

    • Ensure the power supply voltage does not exceed the maximum drain-source voltage (VDS).
    • Provide adequate heat sinking if operating near the maximum continuous drain current (ID).
  2. Gate Drive:

    • Apply gate-source voltage (VGS) within the specified range to avoid damage or unreliable operation.
    • For optimal performance, use a gate drive voltage of 10V to minimize on-resistance (RDS(on)).
  3. Pulse Operation:

    • If using in pulse applications, ensure the pulse duration does not exceed the conditions specified for pulse drain current (IDM).
  4. Capacitance Considerations:

    • Account for input (Ciss), output (Coss), and reverse transfer (Crss) capacitances in circuit design, especially in high-frequency applications.
  5. Storage and Handling:

    • Store in original packaging until ready for use to prevent electrostatic discharge (ESD) damage.
    • Handle with care to avoid mechanical damage to the package and leads.
  6. Mounting:

    • Follow recommended mounting guidelines to ensure proper thermal management and electrical connections.
(For reference only)

View more about CSD58856Q5A on main site